iQ lavatory faucet A30, chrome, IR-sensor, Click, mains operation exposed, with drain assembly, pressureless, G3/8 100.031.11
iQ lavatory faucet A30, with IR sensor, pressureless (for open water heater), with temperature-mixing, chromed
Touchless, electronically controlled lavatory faucet:
• Cold water supply connection and decentralized water treatment (boiler)
• Modular single-piece design without separate installation box, sturdy metal housing, chromed
• Reliable solenoid valve ROBUST (minimal level of water pressure surge) und Spezialstrahlregler
• Dual infrared sensors (with automatic setting feature), microprocessor
• Follow-up time and sensor sensitivity adjustable with function key
• Cold water supply connection for decentralized water treatment (boiler)
• With flexible high-pressure hoses, flow limiters and built-in filters
• Temperature adjustable or fixable (vandal-resistant construction)
• 12, 24 or 48-hour hygienic flush activatable with function key
• Compatible with CNX, Service APP and Service Monitor: control of stored operational data, settings and control functions
• Compatible with Service APP: Control of stored operational data, settings and control functions
Notice:
When integrated into the CNX Water Management System, the CNX Converter 6 V must be ordered separately.
When using the Service APP, the BLE Converter must be ordered separately.
Only possible with mains and VARIOconnect versions.
Mains supply: Plug-in transformer 110-240 V 50-60 Hz / 6 V
Operating pressure: 0,3 – 10 bar
Water temperature (max.): 80 °C
Flow rate (approx.): 5 l/min / 1,3 gpm (3 bar)
Follow-up time: 1 s pre-set (adjustable with function key 0-10 s)
Continuous water flow and hygienic flush time: 2 min pre-set (adjustable with function key 0,5-20 min)
Sensor sensitivity: Automatic self-adapting sensor technology
Built-in filter: 0,5 mm mesh size
Aerator: Flow Straightener, FS Dripless
Flexible hoses: 2x500 mm / 1x350 mm
Angle valve connection: G 3/8
Click: Recessed function key - without additional functions
Engineering standards: DIN EN 200; Noise class I; P-IX 9576 / IA; CE