Skip to main content

CONPRIMUS shower panel stainless steel HB Thermostat-E, E-control, CNX, KWH-flush, cleaning stop CNX, thermal disinfection via CNX, hygiene flush, piezo push-button, CNX bus 30V/DC, thermostat, DN15 CONE1211219568

Central faucet management to ensure the hygienic functions of showers, lavatory faucets and urinal flush valvesAutomatic mixed water flush of electronic faucets – with demand-dependent triggering at intervals, time control or a calendar function, as required, either integrated in the CNX water management system or accessed via the Service APP.Thermal flush of faucets by means of a key-switch or as a calendar function in the CNX water management system or via the Service APP.Cold water flush of electronic shower and wash basin faucets integrated into the CNX Water Management System or via the Service APP.The thermostatic mixing device with scald protection ensures safety during the shower.

CONPRIMUS shower panel, stainless steel, thermostat-E, E-control, DN15

Shower panel with electronically controlled mixing device, including scald protection, for wall mounting. Application in new construction building and renovation in commercial, semi-public and public sanitary facilities.

• Pre-installed electronic mixing unit thermostat-E
• Proportional valve mixing unit at shower head height
• Electronic control unit E-control, turn/push button for mixing and start/stop function
• Electronic scald protection
• Temperature adjustment with LED display
• Non-linear temperature adjustment
• Adjustable shower start temperature
• Time-adjustable memory temperature when showering stops
• Hand shower pre-assembled on delivery
• Electronic hygiene rinsing (mixed water temperature)
• Electronic hygiene flushing (cold water side) via CNX
• Electronic thermal disinfection (hot water side) via CNX
• Integration into the CNX Water Management System
• Connection from above or behind
• Incl. mounting material

Mains supply (CNX):
Power supply via 30 V/DC power supply unit in the Control units 64 and 150 and additional 24 V/DC auxiliary power supply

Execution options:
Cold water flush: (Available with software update)
Cold water flush can be set and deactivated per shower or shower group (CNX) as an interval or calendar function using the parameter settings, either integrated in the CNX Water Management System.
CNX Water Management System:
Integration of the shower into the software-controlled Water Management System for the automatic depiction of hygiene, system and safety functions of electronic showers, lavatory faucets and urinal flush valves at the BUS level. Parametrisation of individual devices and device groups. Tamper-proof documentation of all operating, action and function messages.
Water flow times:
The water running times of the shower function can be set - via piezo push-button (E-control) or integrated into the CNX Water Management System - by the parameter settings per shower or shower fitting group (CNX).
Hygienic flush:
The hygiene flush can be carried out by programming via piezo push-button (E-control). Integrated into the CNX Water Management System, the hygiene flush can be set as an interval or calendar function and deactivated by parameter settings per shower or shower fittings group (CNX).
Thermal disinfection:
Thermal disinfection can be set as a calendar function for each shower or shower group (CNX) - integrated in the CNX Water Management System - using the parameter settings for each shower or shower group (CNX).
Cleaning stop:
The operating stop (cleaning stop), interruption of the shower function, can be set as a calendar function per shower or shower group (CNX) through the parameter settings - integrated in the CNX Water Management System.

Notice:
Hand shower must be ordered separately, shown here as an example with CONHEAD rain shower head SHORTY

Operating voltage (CNX): 30 V/DC, additional 24 V/DC
Operating pressure: 2.0-5.0 bar
Water temperature (max.): 70 °C (Short-term for TD 80 °C)
Water temp. thermal disinfection: Short-term for therm. disinfection 80 °C
Flow rate DN15: 0,15 l/s (flow rate controller)
Flow rate for thermal disinfection DN15: 0.05 l/s
- can be set via Service APP and CNX, observe maximum water temperature). Memory temperature setting: after the end of the shower time (or stop by pressing the piezo button again), the set temperature remains stored for 30 s
Water run time setting range: 3 – 180 s
Water running time factory setting: 30 s
Hygienic flushing setting range: factory setting: deactivated, 24, 48 or 72 h, adjustable via piezo button, CNX or Service APP
Preset temperatures: Stand-by temperature when piezo button is triggered 38 °C (can be adjusted from 100 % cold to max. 43 °C (temperature range) via E-Control rotation. If the cold water line fails, the water flow is stopped when 48 °C is reached (factory setting
Memory temperature setting: After the end of the shower time (or stop by pressing the piezo button again), the set temperature remains stored for 30 s
Electronic protection class: IP68
Dimensions (WxHxD): 220x1400x40 mm